Skip to main content

One-year outcomes of polymer-free amphilimus-eluting stents versus durable polymer zotarolimus-eluting stents in patients with diabetes mellitus: a meta-analysis

Abstract

Background

Diabetes mellitus (DM) and cardiovascular diseases often co-exist. Today, percutaneous coronary intervention (PCI) is the preferred revascularization procedure for majority of patients with coronary artery disease. Polymer-free amphilimus-eluting stents (AES) represent a novel elution technology in the current era of drug-eluting stents. In this analysis, we aimed to systematically compare the cardiovascular outcomes which are associated with polymer-free amphilimus-eluting stents (AES) versus the durable polymer zotarolimus-eluting stents (ZES) for the treatment of patients with DM.

Methods

Http://www.ClinicalTrials.gov, EMBASE, Web of Science, MEDLINE, Cochrane database and Google Scholar were searched for publications comparing polymer-free AES versus durable polymer ZES in patients with DM. Selective cardiovascular outcomes were assessed. Statistical analysis was carried out by the latest version of the RevMan software. Risk ratio (RR) with 95% confidence interval (CI) was used to represent the data analysis.

Results

Four studies with a total number of 1795 participants with DM whereby 912 patients were assigned to be revascularized by the polymer-free AES and 883 patients were assigned to be revascularized by the durable polymer ZES were included in this analysis. In patients with DM, at one year, polymer-free AES were associated with significantly lower risk of major adverse cardiac events (MACEs) (RR: 0.69, 95% CI: 0.54–0.88; P = 0.002) and target lesion failure (TLF) (RR: 0.66, 95% CI: 0.48–0.91; P = 0.01) compared to durable polymer ZES. However, there was no significant change in all-cause mortality (RR: 0.79, 95% CI: 0.51–1.22; P = 0.28), cardiac death and the other cardiovascular outcomes. Similar risk of total stent thrombosis (RR: 1.13, 95% CI: 0.60–2.13; P = 0.70), including definite stent thrombosis (RR: 1.12, 95% CI: 0.38–3.31; P = 0.84), probable stent thrombosis (RR: 0.87, 95% CI: 0.37–2.09; P = 0.76), possible stent thrombosis (RR: 1.19, 95% CI: 0.50–2.87; P = 0.69) and late stent thrombosis (RR: 1.00, 95% CI: 0.17–5.72; P = 1.00) as between polymer-free AES and durable polymer ZES in patients with DM.

Conclusions

At 1 year follow-up, polymer-free AES were associated with significantly lower MACEs and TLF compared to durable polymer ZES in these patients with DM, without any increase in mortality, stent thrombosis and other cardiovascular outcomes. However, this analysis is only based on a follow-up time period of one year, therefore, future research should focus on the long term follow-up time period.

Background

Diabetes mellitus (DM) and cardiovascular diseases often co-exist [1]. Patients with DM are more prone to coronary artery disease due to endothelial dysfunction, vascular inflammation and thrombosis which later manifest as myocardial infarction and death [2]. Epidemiologic reports show the global prevalence of DM to rise with over 200 million people (expectation from year 2015 to 2040) [3]. Beside coronary artery disease, patients with DM are more susceptible to adverse cardiovascular outcomes following treatment interventions [4]. Hence, treating this subgroup of patients will become a necessity in the coming years due to an ageing population.

Today, percutaneous coronary intervention (PCI) is the preferred revascularization procedure for majority of the patients based on the number of coronary vessels which were involved, the extent of disease, the co-morbidities that exist, and any other medical condition or previous cardiovascular treatments [5].

Durable polymer everolimus-eluting stents (EES), and zotarolimus-eluting stents (ZES) are among the latest effective drug-eluting stents (DES) which have been used during revascularization of coronary arteries [6, 7]. Even though new-generation DES have been developed, DM has shown to often be an independent factor associated with adverse clinical outcomes following PCI [8].

Polymer-free amphilimus-eluting stents (AES) represent a novel elution technology in the current era of DES [9]. However, the clinical safety and efficacy of polymer-free AES as compared to the latest-generation permanent-polymer ZES have not yet been investigated in larger trials. Trials with a small number of participants, and other retrospective studies have recently investigated the benefits of polymer-free AES.

Patients with DM are most at risk for adverse events, especially ischemic events and stent thrombosis following PCI. It would therefore be interesting to compare a very effective durable polymer ZES with a newer polymer-free AES in patients with DM.

Methods

Search databases and searched strategies

Http://www.ClinicalTrials.gov, EMBASE, Web of Science, MEDLINE (including its subset PubMed), Cochrane database and Google Scholar were searched for publications comparing polymer-free AES versus durable polymer ZES in patients with DM.

The following search terms or phrases were used:

  • Polymer-free Amphilimus-eluting stents versus durable polymer zotarolimus-eluting stents;

  • Polymer-free Amphilimus-eluting stents versus durable polymer zotarolimus-eluting stents and diabetes mellitus;

  • Amphilimus-eluting stents versus zotarolimus-eluting stents.

Abbreviations such as AES and ZES were also used

Inclusion and exclusion criteria

Studies were included if:

  • They compared polymer-free AES versus durable polymer ZES;

  • They included patients with DM;

  • They reported adverse cardiovascular outcomes as their endpoints;

  • They were published in English;

  • They were trials or observational studies.

    Studies were excluded if:

  • They did not include patients with DM;

  • They were systematic reviews, meta-analyses, literature reviews or case studies;

  • They were duplicated studies.

Definitions, outcomes and follow-up

The outcomes which were reported in the original studies have been listed in Table 1. Selective outcomes were assessed, and the endpoints of this analysis included:

  • Major adverse cardiovascular events (MACEs) including a composite outcome of all-cause mortality, myocardial infarction, revascularization ± stroke;

  • Target lesion failure (TLF) which was defined as a composite of cardiac death, target vessel myocardial infarction and target lesion revascularization;

  • All-cause mortality;

  • Cardiac death;

  • Myocardial infarction (MI);

  • Any revascularization;

  • Target lesion revascularization (TLR);

  • Target vessel revascularization (TVR);

  • Total stent thrombosis;

  • Definite stent thrombosis;

  • Probable stent thrombosis;

  • Possible stent thrombosis;

  • Late stent thrombosis.

Table 1 Outcomes which were reported

Outcomes such as acute and sub-acute stent thrombosis, bleeding outcomes and stroke were not assessed since they were reported in only one study, where a comparison would have been impossible.

This analysis had a follow-up time period of 12 months.

Data extraction and quality assessment

The authors independently extracted data from the original studies. After carefully reading the selected studies, data including the authors’ names, year of publication, number of participants with DM who were assigned to polymer-free AES and durable polymer ZES, the type of studies, the baseline features of the participants, the year of participant enrollment, the endpoints which were reported, the total number of events associated with each endpoints were extracted.

During this data extraction process, any disagreement was resolved by carefully discussing the case with the corresponding author who was the one to make a final decision.

The methodological assessment was carried out by the Newcastle Ottawa Scale (NOS) [10] for observational studies, and the recommendations from the Cochrane collaboration [11] for the randomized trials. Grades were allotted signifying low, moderate or high risk of bias.

Statistical analysis

Statistical analysis was carried out by the latest version of the RevMan software, RevMan 5.4. Heterogeneity was assessed by two simple statistical methods. First of all heterogeneity was assessed by the Q statistic test whereby an outcome with a P value less or equal to 0.05 was considered to be statistically significant, and an outcome with a P value above 0.05 was not considered to have reach statistical significance. Heterogeneity was also assessed by the I2 statistical test, whereby heterogeneity increased with an increasing I2 value. If the I2 value was less than 50%, a fixed statistical effect model was used, or else a random statistical effect model was used. Risk ratio (RR) with 95% confidence interval (CI) was used to represent the data analysis.

Sensitivity analysis was also carried out to rule out any influence of a specific study on the outcomes. Publication bias was also visually estimated through funnel plots.

Compliance with ethical guidelines

This study is a meta-analysis, and does not involve experiment on humans or animals carried out by any of the authors. Hence, an ethical or board review approval was not required. Data were extracted from previously published original studies.

Results

Search outcomes

The preferred reporting items in systematic review and meta-analysis (PRISMA) guideline was followed [12]. A total number of 84 publications were obtained. Following a careful assessment of the titles and abstracts, 64 publications were eliminated due to irrelevance. Twenty (20) full text articles were assessed for eligibility. Further eliminations were carried out due to the following reasons:

  • Studies were based on the same trial, that is, same data were used (4);

  • Duplicated studies (12).

Finally, only 4 studies [13,14,15,16] were selected for this analysis. The flow diagram for the study selection has been represented by Fig. 1.

Fig. 1
figure 1

Flow diagram showing the study selection

Main features of the studies

A total number of 1795 participants with DM were included in this analysis, whereby 912 patients were assigned to be revascularized by the polymer-free AES and 883 patients were assigned to be revascularized by the durable polymer ZES as shown in Table 2. This analysis included 4 studies whereby two studies were randomized trials and another two studies were observational studies. Based on the methodological assessment, a grade “B” was allotted to the studies implying moderate risk of bias.

Table 2 General features of the studies

Baseline characteristics of the participants

The baseline characteristics of the DM participants were listed in Table 3. Majority of the participants were males (64.5% to 82.4%) with a mean age ranging from 65.9 to 69.2 years. Risk factors such as smoker (18.3% to 39.6%), hypertension (57.1% to 96.5%) and dyslipidemia (40.3% to 91.9%) were also listed in Table 3.

Table 3 Baseline features of the participants with diabetes mellitus

Main results of this analysis

Results of this analysis showed that in patients with DM, at one year, polymer-free AES were associated with significantly lower risk of MACEs (RR: 0.69, 95% CI: 0.54 – 0.88; P = 0.002) and TLF (RR: 0.66, 95% CI: 0.48–0.91; P = 0.01) compared to durable polymer ZES as shown in Fig. 2. However, there was no significant change in all-cause mortality (RR: 0.79, 95% CI: 0.51–1.22; P = 0.28), cardiac death (RR: 0.75, 95% CI: 0.42–1.33; P = 0.32), MI (RR: 0.80, 95% CI: 0.53–1.20; P = 0.28), any revascularization (RR: 0.80, 95% CI: 0.59–1.10; P = 0.18), TLR (RR: 0.67, 95% CI: 0.39–1.14; P = 0.14), and TVR (RR: 0.74, 95% CI: 0.48–1.13; P = 0.16) as shown in Fig. 2. Similar risk of total stent thrombosis (RR: 1.13, 95% CI: 0.60–2.13; P = 0.70), including definite stent thrombosis (RR: 1.12, 95% CI: 0.38–3.31; P = 0.84), probable stent thrombosis (RR: 0.87, 95% CI: 0.37–2.09; P = 0.76), possible stent thrombosis (RR: 1.19, 95% CI: 0.50–2.87; P = 0.69) and late stent thrombosis (RR: 1.00, 95% CI: 0.17–5.72; P = 1.00) as between polymer-free AES and durable polymer ZES in patients with DM as shown in Fig. 3.

Fig. 2
figure 2

Cardiovascular outcomes observed with polymer-free AES versus durable polymer ZES in patients with DM

Fig. 3
figure 3

Stent thrombosis observed with polymer-free AES versus durable polymer ZES in patients with DM

Sensitivity analysis resulted in consistent results throughout. Publication bias was visually assessed through funnel plot. Based on this visual assessment, there was very little evidence of publication bias among the studies which were used to assess the clinical endpoints as shown in Fig. 4.

Fig. 4
figure 4

Funnel plot showing publication bias

This comparison of outcomes between polymer-free AES versus durable polymer ZES in patients with DM has been summarized in Table 4.

Table 4 Results of this analysis

Discussion

In this analysis, we compared the cardiovascular outcomes with polymer-free AES versus durable polymer ZES in patients with DM. The current results showed polymer-free AES to be associated with significantly lower TLF and MACEs in comparison to the durable polymer ZES in these patients with DM. Other outcomes including all-cause mortality, cardiac death, MI, TVR, TLR, and stent thrombosis were not significantly different.

Similarly, in the Randomized “All-comer” Evaluation of a Permanent Polymer Resolute Integrity Stent versus a Polymer FreeCre8 Stent (ReCre8) Landmark Analysis, a premiere in the head to head comparison comparing 3-year clinical outcomes after implantation of permanent-polymer versus polymer-free stents whereby a total number of 1491 participants were randomized and treated, the authors showed a similar rate of revascularization, mortality and stent thrombosis. In contrast, our results showed polymer-free AES to be associated with a significant decrease in the risk of TLF and MACEs [17]. It should be noted that our current study only involved participants with DM in contrast to the other study which included participants from the general population with coronary artery disease. A substudy of the ReCre8 trial consisting only of patients with DM showed composite of net adverse clinical events to be significantly higher with durable polymer ZES, and TLF was also higher with ZES among patients with insulin-treated DM [13].

Studies based on polymer-free AES versus durable polymer ZES in patients with DM were very limited. A randomized comparison of reservoir-based polymer-free AES versus durable polymer everolimus eluting stents (EES) in patients with diabetes mellitus (RESERVOIR trial) which was a multicenter, prospective, open-label, assessor-blinded, active treatment-controlled, randomized clinical trial and involving 112 participants with diabetes mellitus, with 40% insulin-treated patients, suggested a higher efficacy of AES which might be more beneficial in patients with DM [18].

New studies have shown chronic total occlusion to be more common among patients with DM. A multicenter experience based on the outcomes of the polymer-free AES for chronic total occlusion treatment and involving 235 participants demonstrated a lower rate of MACEs and target vessel failure for up to one year with the polymer-free stents supporting their use [19].

Other factors to be considered

However, several other factors should be taken into consideration. A retrospective study involving 1574 patients with ACS undergoing coronary stenting showed that insulin resistance, represented by the triglyceride-glucose index, was independently and positively associated with DES in-stent restenosis [20]. This analysis was based on patients with diabetes mellitus, however, not only patients with diabetes mellitus but, patients with pre-diabetes were at a higher risk for ischemic events following newer generation stents implantation. This was shown in a post-hoc analysis whereby data from the BIO-RESORT and BIONYX stent trials were pooled for study analysis [21]. In addition, when second generation DES were compared with first generation DES, stent related adverse events were significantly lower with the second generation DES, however, it was observed that the use of dual antiplatelet therapy beyond one year did not reduce late stent thrombosis among patients who were revascularized with second generation DES, but late stent thrombosis was reduced in patients who were implanted with first generation DES [22]. It should also be noted that in a prospective study with over 7000 participants with diabetes mellitus, similar 3-year risk for TVF was observed with various types of contemporary DES [23].

Novelty

At last, this manuscript is new in several ways. It is the first meta-analysis to assess the cardiovascular outcomes between polymer-free AES versus durable polymer ZES in patients with coronary artery disease with co-existing DM. Durable polymer ZES are still new drug eluting stents. A comparison between the most recent polymer-free AES versus the newer durable polymer ZES is a novelty in itself. This analysis has significant clinical implications in the way that better stents could be implanted in patients with DM, who are more at risk for thrombosis and ischemic events. By carrying out this research analysis, we expect to promote and encourage further research based on polymer-free AES and diabetes mellitus.

Limitations

This study has certain limitations. First of all, we had a limited number of participants who were involved in the comparison of outcomes between polymer-free AES versus durable polymer ZES in these patients with DM, which could have an effect on the final outcomes. Another limitation might be the fact that several endpoints including stroke, acute and sub-acute stent thrombosis as well as bleeding events could not be assessed in this study because they were reported in only one original study, without data from other studies to compare. Moreover, even though cardiovascular drugs and extent of coronary occlusion and number of obstructed coronary arteries could also have had an impact on the final outcomes, they were not taken into consideration in this analysis. The duration of diabetes mellitus, and the number of participants on insulin therapy were ignored since several of the original studies did not report those details. At last, the permanent polymers ZES which were used were different in different studies. This could also have an impact on the results of this analysis.

Conclusions

At 1 year follow-up, polymer-free AES were associated with significantly lower MACEs and TLF compared to durable polymer ZES in these patients with DM, without any increase in mortality, stent thrombosis and other cardiovascular outcomes. However, this analysis is only based on a follow-up time period of one year, therefore, future research should focus on the long term follow-up time period.

Availability of data and materials

All data and materials used in this research are freely available in electronic databases (MEDLINE, EMBASE, http://www.ClinicalTrials.gov, Web of Science, Cochrane database, Google scholar). References have been provided.

Abbreviations

DM:

Diabetes mellitus

AES:

Amphilimus-eluting stents

ZES:

Zotarolimus-eluting stents

PCI:

Percutaneous coronary intervention

MACEs:

Major adverse cardiac events

RR:

Risk ratio

References

  1. Henning RJ. Type-2 diabetes mellitus and cardiovascular disease. Future Cardiol. 2018;14(6):491–509.

    Article  CAS  PubMed  Google Scholar 

  2. Rodriguez-Araujo G, Nakagami H. Pathophysiology of cardiovascular disease in diabetes mellitus. Cardiovasc Endocrinol Metab. 2018;7(1):4–9.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  3. Ogurtsova K, Fernandes JDR, Huang Y, et al. Diabetes Atlas: global estimates for the prevalence of diabetes for 2015 and 2040. Diabetes Res Clin Pract. 2017;128:40–50.

    Article  CAS  PubMed  Google Scholar 

  4. Ashley KE, Hillegass WB. Insulin-treated diabetes mellitus: an actionable risk factor and marker after percutaneous coronary intervention. Catheter Cardiovasc Interv. 2020;96(2):309–10.

    Article  PubMed  Google Scholar 

  5. Park DW, Ahn JM, Park SJ, Taggart DP. Percutaneous coronary intervention in left main disease: SYNTAX, PRECOMBAT, EXCEL and NOBLE-combined cardiology and cardiac surgery perspective. Ann Cardiothorac Surg. 2018;7(4):521–6.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Bavishi C, Baber U, Panwar S, Pirrotta S, Dangas GD, Moreno P, Tamis-Holland J, Kini AS, Sharma SK. Efficacy and safety of everolimus and zotarolimus-eluting stents versus first-generation drug-eluting stents in patients with diabetes: a meta-analysis of randomized trials. Int J Cardiol. 2017;230:310–8.

    Article  PubMed  Google Scholar 

  7. Piccolo R, Stefanini GG, Franzone A, et al. Safety and efficacy of resolute zotarolimus-eluting stents compared with everolimus-eluting stents: a meta-analysis. Circ Cardiovasc Interv. 2015;8(4):e002223.

    Article  CAS  PubMed  Google Scholar 

  8. Bundhun PK, Li N, Chen M. Adverse cardiovascular outcomes between insulin-treated and non-insulin treated diabetic patients after percutaneous coronary intervention: a systematic review and meta-analysis. Cardiovasc Diabetol. 2015;14:135.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Carrié D. Advances with polymer-free amphilimus-eluting stents. Minerva Cardioangiol. 2016;64(3):339–53.

    PubMed  Google Scholar 

  10. Stang A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol. 2010;25(9):603–5.

    Article  PubMed  Google Scholar 

  11. Higgins JPT, Altman DG, Gøtzsche PC, et al. The Cochrane collaboration’s tool for assessing risk of bias in randomised trials. BMJ. 2011;343:d5928.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Liberati A, Altman DG, Tetzlaff J, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ. 2009;339:b2700.

    Article  PubMed  PubMed Central  Google Scholar 

  13. van Hemert ND, Rozemeijer R, Voskuil M, et al. Clinical outcomes after permanent polymer or polymer-free stent implantation in patients with diabetes mellitus: the ReCre8 diabetes substudy. Catheter Cardiovasc Interv. 2022;99(2):366–72.

    Article  PubMed  Google Scholar 

  14. Romaguera R, Salinas P, Gomez-Lara J, et al. Amphilimus- vs. zotarolimus-eluting stents in patients with diabetes mellitus and coronary artery disease: the SUGAR trial. Eur Heart J. 2022;43(13):1320–30.

    Article  CAS  PubMed  Google Scholar 

  15. Rozemeijer R, Benedetto D, Kraaijeveld AO, et al. Clinical outcomes of complex real-world diaetic patients treated with amphilimus sirolimus-eluting stents or zotarolimus-eluting stents: a single-center registry. Cardiovasc Revasc Med. 2018;19(5 Pt A):521–5.

    Article  PubMed  Google Scholar 

  16. Rozemeijer R, van Muiden IG, Koudstaal S, et al. One-year clinical outcomes of patients treated with polymer-free amphilimus-eluting stents or zotarolimus-eluting stents: a propensity-score adjusted analysis. Catheter Cardiovasc Interv. 2019;94(1):61–9.

    Article  PubMed  PubMed Central  Google Scholar 

  17. van Hemert ND, Voskuil M, Rozemeijer R, et al. 3-Year clinical outcomes after implantation of permanent-polymer versus polymer-free stent: ReCre8 landmark analysis. JACC Cardiovasc Interv. 2021;14(22):2477–86.

    Article  PubMed  Google Scholar 

  18. Romaguera R, Gómez-Hospital JA, Gomez-Lara J, et al. A randomized comparison of reservoir-based polymer-free amphilimus-eluting stents versus everolimus-eluting stents with durable polymer in patients with diabetes mellitus: the RESERVOIR clinical trial. JACC Cardiovasc Interv. 2016;9(1):42–50.

    Article  PubMed  Google Scholar 

  19. Maeremans J, Cottens D, Azzalini L, et al. Outcomes of the amphilimus-eluting polymer-free stent for chronic total occlusion treatment: a multicentre experience. J Cardiovasc Med (Hagerstown). 2018;19(10):564–70.

    Article  CAS  Google Scholar 

  20. Zhu Y, Liu K, Chen M, et al. Triglyceride-glucose index is associated with in-stent restenosis in patients with acute coronary syndrome after percutaneous coronary intervention with drug-eluting stents. Cardiovasc Diabetol. 2021;20(1):137.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  21. Ploumen EH, Pinxterhuis TH, Zocca P, et al. Impact of prediabetes and diabetes on 3-year outcome of patients treated with new-generation drug-eluting stents in two large-scale randomized clinical trials. Cardiovasc Diabetol. 2021;20(1):217.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  22. Yoshikawa Y, Shiomi H, Morimoto T, et al. Stent-related adverse events as related to dual antiplatelet therapy in first- vs second-generation drug-eluting stents. JACC Asia. 2021;1:345–56.

    Article  Google Scholar 

  23. Yang Y, Hyun J, Lee J, et al. Effectiveness and safety of contemporary drug-eluting stents in patients with diabetes mellitus. JACC Asia. 2021;1:173–84.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This research was supported by the Guangxi Key Research and Development Program (Grant No. AB22035078); Guangxi Medical and Health Appropriate Technology Development and Promotion Application Project (Grant No. S2017077) and the Guangxi Nanning Qingxiu District Science and Technology Development Project (Grant No. 2014S06).

Author information

Authors and Affiliations

Authors

Contributions

HW, XX, QZ, ML, RC, ZY, and YG were responsible for the conception and design, drafting the initial manuscript and revising it critically for important intellectual content. HW and XX wrote the final draft. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Hong Wang.

Ethics declarations

Ethics approval and consent to participate

Ethical approval was not applicable for this systematic review and meta-analysis.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wang, H., Xie, X., Zu, Q. et al. One-year outcomes of polymer-free amphilimus-eluting stents versus durable polymer zotarolimus-eluting stents in patients with diabetes mellitus: a meta-analysis. Cardiovasc Diabetol 21, 220 (2022). https://doi.org/10.1186/s12933-022-01673-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12933-022-01673-8

Keywords