Skip to main content
  • Original investigation
  • Open access
  • Published:

Everolimus-eluting bioresorbable scaffolds and metallic stents in diabetic patients: a patient-level pooled analysis of the prospective ABSORB DM Benelux Study, TWENTE and DUTCH PEERS

Abstract

Background

Several studies compared everolimus-eluting bioresorbable scaffolds (EE-BRS) with everolimus-eluting stents (EES), but only few assessed these devices in patients with diabetes mellitus.

Aim

To evaluate the safety and efficacy outcomes of all-comer patients with diabetes mellitus up to 2 years after treatment with EE-BRS or EES.

Methods

We performed a post hoc pooled analysis of patient-level data in diabetic patients who were treated with EE-BRS or EES in 3 prospective clinical trials: The ABSORB DM Benelux Study (NTR5447), TWENTE (NTR1256/NCT01066650) and DUTCH PEERS (NTR2413/NCT01331707). Primary endpoint of the analysis was target lesion failure (TLF): a composite of cardiac death, target vessel myocardial infarction or clinically driven target lesion revascularization. Secondary endpoints included major adverse cardiac events (MACE): a composite of all-cause death, any myocardial infarction or clinically driven target vessel revascularization, as well as definite or probable device thrombosis (ST).

Results

A total of 499 diabetic patients were assessed, of whom 150 received EE-BRS and 249 received EES. Total available follow-up was 222.6 patient years (PY) in the EE-BRS and 464.9 PY in the EES group. The adverse events rates were similar in both treatment groups for TLF (7.2 vs. 5.2 events per 100 PY, p = 0.39; adjusted hazard ratio (HR) = 1.48 (95% confidence interval (CI): 0.77–2.87), p = 0.24), MACE (9.1 vs. 8.3 per 100 PY, p = 0.83; adjusted HR = 1.23 (95% CI: 0.70–2.17), p = 0.47), and ST (0.9 vs. 0.6 per 100 PY, p > 0.99).

Conclusion

In this patient-level pooled analysis of patients with diabetes mellitus from 3 clinical trials, EE-BRS showed clinical outcomes that were quite similar to EES.

Background

Diabetes mellitus is a well-established predictor of adverse clinical and angiographic events following percutaneous coronary intervention (PCI) with metallic drug-eluting stents (DES) for obstructive coronary artery disease (CAD) [1,2,3,4,5,6]. Various disease-related factors contribute to a pro-inflammatory and pro-thrombotic state that reduce the prognosis of patients with diabetes mellitus, such as endothelial dysfunction, changes in plaque composition, platelet activation and coagulation disturbances [7]. Following PCI with stent implantation, the aforementioned mechanisms may be even aggravated by the permanent presence of the metallic vascular prosthesis that mechanically distorts the arterial geometry, delays vascular healing and constrains vascular response in the treated coronary segment [8,9,10].

The everolimus-eluting bioresorbable scaffolds (EE-BRS) were developed to overcome some shortcomings of the metallic DES [11, 12]. Because of its resorbable nature and its transient presence after implantation, it was hypothesized that EE-BRS may be associated with a more favorable restoration of the treated coronary vessel and a more favorable long-term clinical outcome. In addition, the use of EE-BRS may allow for repeating PCI in the same target lesion without loss of lumen size due to the lifelong presence of multiple layers of metallic stents in the coronary vessel. Furthermore, it is likely to facilitate coronary artery bypass grafting (CABG) that may be required at a later point in time. Consequently, patients with diabetes mellitus, who are known to have an increased risk of repeated PCI and finally surgical treatment with CABG, may show a particular benefit from PCI with the utilization of EE-BRS.

Nevertheless, data from studies that compare EE-BRS and DES in an all-diabetic patient population are scarce. For that reason, we pooled patient-level data from 3 prospective clinical trials to compare the clinical outcome after PCI with EE-BRS and everolimus-eluting stents (EES) in all-comers with diabetes mellitus.

Methods

Study population

For the purpose of this analysis we pooled data of all patients with diabetes mellitus, who were treated with EE-BRS in de novo coronary lesions in the prospective ABSORB DM Benelux Study or who underwent PCI with EES in de novo coronary lesions in the TWENTE and DUTCH PEERS trials. The design and outcomes of the individual studies have been reported previously [13,14,15,16]. The ABSORB DM Benelux Study is a prospective, international observational study in all-comer patients with diabetes mellitus who underwent PCI with EE-BRS. The TWENTE study is a Dutch randomized trial that examined the performance of second-generation EES to zotarolimus-eluting stents in all-comers. DUTCH PEERS is a Dutch multicenter randomized trial that assessed the performance of new-generation EES to zotarolimus-eluting stents in an all-comer population. All available follow-up data up to 2 years after PCI was used.

Percutaneous coronary intervention procedure

Implanted EE-BRS devices were the bioresorbable polymer drug-eluting scaffold ABSORB BVS system and the ABSORB GT1 system (Abbott Vascular, Santa Clara, CA, USA). Both devices are composed of poly-L-lactic acid with a strut thickness of 150 µm, covered by a polymer coating of poly-DL-lactic-acid that elutes everolimus. EE-BRS are expected to be completely resorbed within 3 years [12]. The available scaffold diameters ranged from 2.50 to 3.50 mm with lengths of 8–28 mm. The durable fluoropolymer-coated Xience V EES (Abbott Vascular, Santa Clara, CA, USA) is a cobalt-chromium EES with a strut thickness of 81 µm; it was available in diameters from 2.25 to 4.00 mm with lengths of 8 to 28 mm. The strut thickness, polymer coating, eluted drug and available stent diameters of the platinum-chromium-based Promus Element EES (Boston Scientific, Natick, MA, USA) were the same as for Xience V EES; the available stent length ranged from of 8 to 38 mm.

Angiographic success was defined as a < 50% residual stenosis of the target lesion after successful device implantation, as visually assessed. Procedural success was defined as angiographic success without occurrence of any adverse cardiac event during index hospitalization. In general, dual antiplatelet therapy (DAPT) was prescribed for 12 months after PCI, reflecting contemporary international guideline recommendations.

Study endpoints

The primary device-oriented endpoint of target lesion failure (TLF) is a composite of cardiac death, target vessel myocardial infarction (TV-MI) or clinically driven target lesion revascularization (TLR). Secondary endpoints include the patient-oriented endpoint of major adverse cardiac events (MACE), which is defined as a composite of all-cause death, any myocardial infarction (MI) or clinically driven target vessel revascularization (TVR), as well as definite or probable device (i.e., scaffold or stent) thrombosis (ST). All endpoints were defined according to clinical data standards of the American College of Cardiology/American Heart Association and the Academic Research Consortium [17,18,19,20].

Statistical analysis

Categorical variables are presented as frequencies and percentages. A 2-sided Pearson’s Chi square test was performed to determine significant differences between the EE-BRS and EES groups. The Fisher’s exact test was used if appropriate due to small sample sizes with low frequency variables. Continuous variables with normal distribution are presented as mean and standard deviation, and a 2-sided independent student t-test was used to compare groups. An equal variance was upheld unless a significant Levene’s test had been calculated; in that case a t-test with unequal variances was conducted. The clinical outcomes of the composite endpoints TLF and MACE were obtained by means of Kaplan–Meier survival methods with time-to-event analysis in addition to a log-rank test at 2-year follow-up. To adjust for variable time to follow-up between trials, all endpoints and the composites of TLF and MACE are presented in event rates per 100 patient years (PY) with the Poisson distribution given with 95% confidence interval (CI). In addition, a multivariate Cox regression model with adjustment for age, insulin-treated diabetes mellitus, number of treated vessels, total treated vessel length and treatment group was built for both TLF and MACE, reported as hazard ratio (HR) and 95% CI. P-values < 0.05 were considered statistically significant. Statistical analyses were performed using SPSS version 25 (IBM Corp., Armonk, NY, USA).

Results

Patient-level data were available from 499 diabetic patients; 150 patients (188 target lesions) were treated with EE-BRS and 249 (336 target lesions) with EES. Baseline clinical characteristics of both patient groups are shown in Table 1. Patients treated with EE-BRS were younger and had less frequently a family history of cardiovascular disease. Other baseline characteristics, including previous ischemic heart disease, the prescription of insulin and the clinical presentation at the time of the index PCI did mostly not differ between the groups. The incidence of chronic kidney failure (serum creatinine levels of ≥ 130 µmol per liter), as determinant risk factor for cardiovascular disease, was limited and also did not differ between both study populations.

Table 1 Clinical characteristics of the patients at baseline

The angiographic characteristics are presented in Table 2. There was no significant difference in the distribution of the target vessels, except for left main stem treatment which was only performed in a few EES-treated patients. In the EE-BRS group, a few patients with CABG treatment were included. Although the number of target lesions per patient was similar in both groups, the EES group had a greater number of treated vessels, which resulted in a longer total device length. In addition, the EES group underwent more often bifurcation treatment. Nevertheless, both treatment groups showed similar angiographic and procedural results.

Table 2 Angiographic characteristics of the patients at baseline

Follow-up was available for all but 3 patients who were lost to follow-up. Total available follow-up was 222.6 PY for the EE-BRS and 464.9 PY for the EES arm. Clinical outcomes are reported in Table 3 and Figs. 1 and 2. In all clinical endpoints, there was no significant difference between EE-BRS and EES. TLF event rates were 7.2 vs. 5.2 events per 100 PY (p = 0.39) (adjusted HR 1.48, 95% CI 0.77–2.87; p = 0.24). The rates of MACE were 9.1 vs. 8.3 events per 100 PY (p = 0.83) (adjusted HR 1.23, 95% CI: 0.70–2.17; p = 0.47). No significant difference was observed in any individual component of these composite endpoints. ST rates were 0.9 vs. 0.6 per 100 PY (p > 0.99). Table 4 present the results of the multivariate Cox regression model for TLF and MACE. After correction for age, insulin-treated diabetes mellitus, multiple vessel treatment and total treated length, we found again no significant difference between EE-BRS and EES. Nevertheless, multivariable analysis revealed borderline non-significant relations between insulin-treatment and TLF (p = 0.06) and between patient age and MACE (p = 0.06).

Table 3 Safety and efficacy outcomes at follow-up
Fig. 1
figure 1

Shown are the Kaplan–Meier curves with 95% confidence intervals in function of a target lesion failure free survival and b major adverse cardiac events free survival at 2-year follow-up. A log-rank test did not prove significant differences between both treatment groups. In a Cox regression model with adjustment for age, insulin-treated diabetes mellitus, number of treated vessels and total treated length, treatment with everolimus-eluting bioresorbable scaffolds could not be identified as significant risk factor for both target lesion failure and major adverse cardiac events. TLF target lesion failure, EE-BRS everolimus-eluting bioresorbable scaffolds, EES everolimus-eluting stents, HR hazard ratio, CI confidence interval, MACE major adverse cardiac events

Fig. 2
figure 2

Shown are the event rates per 100 patient years for the composite endpoints a target lesion failure and b major adverse cardiac events for both treatment groups (red and blue bars). In addition, the 95% confidence intervals are also presented (red and blue brackets). No significant differences were found between both treatment groups. TLF target lesion failure, CI confidence interval, EE-BRS everolimus-eluting bioresorbable scaffolds, EES everolimus-eluting stents, MACE major adverse cardiac events

Table 4 Multivariate Cox regression models for target lesion failure and major adverse cardiac events

Discussion

This analysis of pooled patient-level data, comparing EE-BRS with EES for treatment of CAD in patients with diabetes mellitus, showed similar event rates in both treatment groups for the device-oriented and the patient-oriented composite endpoint. Importantly, safety outcomes were also similar, including cardiac death and TV-MI. A multivariable analysis for the composite clinical endpoints TLF and MACE confirmed the absence of a significant difference between both groups.

Comparing EE-BRS to EES in a wider perspective

Despite advances in interventional therapies and the implementation of new-generation DES, diabetic patients still have worse angiographic and clinical outcomes compared to nondiabetic patients undergoing PCI [21]. Nevertheless, as shown in the EXCEL trial, the relative 30-day and 3-year outcomes of PCI with EES compared to CABG were consistent in diabetic and nondiabetic patients with left main disease with low or intermediate SYNTAX score [22]. Other factors like renal failure and hemodialysis as well as in-stent restenosis, both occurring more frequently in diabetic patients, might influence safety outcomes in this group [23].

In the present analysis, diabetic patients treated with EES showed clinical event rates similar to those of the EES-treated diabetic patients in a pooled analysis of the SPIRIT and COMPARE trials [6]. Furthermore, in our patients with diabetes mellitus the efficacy and short- and long-term safety of EE-BRS treatment were favorable and comparable to previous studies [24,25,26,27]. The performance of EE-BRS and EES have been compared in non-exclusive diabetic populations. Despite some promising early results, long-term assessment revealed no advantage for treating all-comers with EE-BRS, but revealed a higher incidence of TV-MI and ST, and a greater angiographic late lumen loss [28,29,30,31,32]. The findings of these trials led to the current withdrawal and utilization of EE-BRS and suggest a need for refined bioresorbable devices and a modified duration of DAPT (to correspond with scaffold resorption). Yet, it should be considered that in these previous trials operator experience with EE-BRS implantation was limited and that there was no requirement to follow a formal EE-BRS implantation protocol such as the pre-dilatation, sizing, and post-dilatation (PSP) approach, which in other studies improved safety outcomes [33,34,35]. Interestingly, a 3-year landmark analysis of the ABSORB trials showed a significant improvement in composite safety outcomes beyond the resorption of the EE-BRS [36, 37].

Nevertheless, previous trials did not focus exclusively on diabetic patients. Patients with diabetes mellitus represent a high-risk population that theoretically might show particular benefit from being treated with bioresorbable devices. This is because such devices ‘disappear’ over time, which allows for repeated PCI procedures in the same coronary segment without resulting in multiple metallic mesh layers. Furthermore, the EE-BRS does not cause an incessant stimulation of the diabetes-related vascular inflammation, which may be the case in the permanent presence of certain durable polymers. Therefore, it is conceivable that after PCI with EE-BRS long-term results might be more favorable in patients with diabetes mellitus (despite short and medium-term results similar to EES).

Revascularization in insulin-treated diabetic patients

In our current all-diabetic patient population, treatment with insulin showed an, albeit statistically non-significant, trend towards prediction of TLF. Such relation was observed in the diabetes mellitus subgroup analysis of the ABSORB trials and in a pooled analysis of the SPIRIT and COMPARE trials; both analyses found insulin-treatment to be a risk factor for TLF after PCI with either EE-BRS or EES [6, 24]. The increased event risk in insulin-treated patients may be attributable to the generally longer history of diabetes mellitus, during which the diabetes-induced chronic vascular inflammation stimulates the progression of atherosclerosis, alters plaque composition and promotes the development of advanced lesions. It is plausible that the severity and duration of diabetes mellitus is related to the risk of cardiovascular complications and it appears reasonable to consider this when choosing a coronary revascularization strategy.

Patient selection for EE-BRS treatment

Younger patients with non-insulin-treated diabetes mellitus and CAD of limited extent may be the most suitable candidates for treatment with EE-BRS (as an alternative to EES), as they might have the greatest benefit from the bioresorbable nature of the device. Furthermore, younger patients have a lower bleeding risk than elderly patients, which is beneficial considering that a prolonged DAPT regimen may be indicated following PCI with EE-BRS. Nevertheless, further dedicated research is required to assess the usefulness of EE-BRS in younger patients. Most likely, such studies will test novel thinner-strut bioresorbable scaffolds that recently became available for research purposes and these studies should include a long-term follow-up [38].

Limitations

The hypothesis-generating findings of the present post hoc analysis should be interpreted carefully in the light of several limitations, including the intrinsic limitations of any comparison between multiple patient cohorts from different studies. Low cholesterol, and in particular values of remnant-like particle cholesterol below 0.5 mmol per liter have shown to be a predictor of freedom from in-stent restenosis in diabetic patients for all types of stents [39]. In our study detailed patient specific cholesterol values were unobtainable, however a dichotomic hypercholesterolemia (treated) was available and similarly distributed between both groups. Profound data concerning the status of diabetes mellitus and medication prescription were unavailable for a substantial share of the included patients. Yet, all study participants were treated in the same geographical region and they received the same concomitant medication reflecting the international guidelines. Although most baseline clinical characteristics were fairly comparable, there were some differences in angiographic lesion characteristics. Hence, a multivariable analysis was performed, striving for adjustment of known confounders. Due to the population size, this study was not powered to detect significant differences in the composites of the endpoints, particularly low-incidence events like mortality and ST, therefore these results should be interpreted with necessary caution. As we decided to share our results now as debate concerning the future of bioresorbable devices continues, this study does not provide sufficient information about differences between these devices in the phase beyond scaffold resorption in the majority of the EE-BRS patients. To correct for the variable time to follow-up, results were presented in PY which theoretically may obscure time-to-event related adverse outcomes. To minimize this limitation we also reported time-to-event analysis and the nominal incidence of ST. While the operators had considerable experience with implanting EE-BRS, the use of the PSP approach and intracoronary imaging were not mandatory according to the study protocol, while this might have improved clinical outcomes. Finally, as the current EE-BRS generation has been withdrawn from daily practice due to the comprised safety outcomes, the clinical implication of our results should be interpreted in the light of newer bioresorbable devices which have been introduced recently.

Conclusion

In this patient-level pooled analysis of diabetic patients from 3 prospective clinical trials, EE-BRS showed similar clinical outcomes to EES. These results encourage further prospective long-term follow-up research with novel bioresorbable scaffolds in this patient population.

Availability of data and materials

The dataset used and/or analyzed in the current manuscript was pooled from 3 individual clinical trials. Consequently, the authors of this manuscript do not own the underlying patient-level data. Upon reasonable request, data may be available from the respective organizing centers, but not without formal permission of the principal investigators and the steering committees of each of the separate trials. Corresponding author for any data request is E. Kedhi, the senior corresponding author of this manuscript.

Abbreviations

CABG:

Coronary artery bypass grafting

CAD:

Coronary artery disease

CI:

Confidence interval

DAPT:

Dual antiplatelet therapy

EE-BRS:

Everolimus-eluting bioresorbable scaffolds

EES:

Everolimus-eluting stents

HR:

Hazard ratio

MACE:

Major adverse cardiac events

MI:

Myocardial infarction

PCI:

Percutaneous coronary intervention

PSP:

Pre-dilatation, sizing, and post-dilatation

PY:

Patient years

ST:

Device thrombosis

TLF:

Target lesion failure

TLR:

Target lesion revascularization

TV-MI:

Target vessel myocardial infarction

TVR:

Target vessel revascularization

References

  1. Ritsinger V, Saleh N, Lagerqvist B, Norhammer A. High event rate after a first percutaneous coronary intervention in patients with diabetes mellitus: results from the Swedish coronary angiography and angioplasty registry. Circ Cardiovasc Interv. 2015;8:e002328.

    Article  Google Scholar 

  2. Singh M, Gersh BJ, McClelland RL, et al. Clinical and angiographic predictors of restenosis after percutaneous coronary intervention: insights from the prevention of restenosis with tranilast and its outcomes (PRESTO) trial. Circulation. 2004;109:2727–31.

    Article  Google Scholar 

  3. Van Belle E, Périé M, Braune D, et al. Effects of coronary stenting on vessel patency and long-term clinical outcome after percutaneous coronary revascularization in diabetic patients. J Am Coll Cardiol. 2002;40:410–7.

    Article  Google Scholar 

  4. Grube E, Chevalier B, Guagliumi G, et al. The SPIRIT V diabetic study: a randomized clinical evaluation of the XIENCE V everolimus-eluting stent vs the TAXUS Liberté paclitaxel-eluting stent in diabetic patients with de novo coronary artery lesions. Am Heart J. 2012;163:867–75.

    Article  CAS  Google Scholar 

  5. Jensen LO, Maeng M, Thayssen P, et al. Influence of diabetes mellitus on clinical outcomes following primary percutaneous coronary intervention in patients with ST-segment elevation myocardial infarction. Am J Cardiol. 2012;109:629–35.

    Article  Google Scholar 

  6. Stone GW, Kedhi E, Kereiakes DJ, et al. Differential clinical responses to everolimus-eluting and paclitaxel-eluting coronary stents in patients with and without diabetes mellitus. Circulation. 2011;124:893–900.

    Article  CAS  Google Scholar 

  7. Moreno PR, Fuster V. New aspects in the pathogenesis of diabetic atherothrombosis. J Am Coll Cardiol. 2004;44:2293–300.

    Article  CAS  Google Scholar 

  8. Yamaji K, Kimura T, Morimoto T, et al. Very long-term (15 to 20 years) clinical and angiographic outcome after coronary bare metal stent implantation. Circ Cardiovasc Interv. 2010;3:468–75.

    Article  Google Scholar 

  9. Otsaka F, Vorpahl M, Nakano M, et al. Pathology of second-generation everolimus-eluting stents versus first-generation sirolimus- and paclitaxel-eluting stents in humans. Circulation. 2014;129:211–23.

    Article  Google Scholar 

  10. Iqbal J, Serruys PW, Silber S, et al. Comparison of zotarolimus- and everolimus-eluting coronary stents: final 5-year report of the RESOLUTE all-comers trial. Circ Cardiovasc Interv. 2015;8:e002230.

    PubMed  Google Scholar 

  11. Kereiakes DJ, Onuma Y, Serruys PW, Stone GW. Bioresorbable vascular scaffolds for coronary revascularization. Circulation. 2016;134:168–82.

    Article  CAS  Google Scholar 

  12. Tenekecioglu E, Farooq V, Bourantes CV, et al. Bioresorbable scaffolds: a new paradigm in percutaneous coronary intervention. BMC Cardiovasc Disord. 2016;16:38.

    Article  Google Scholar 

  13. Hommels TM, Hermanides RS, Rasoul S, et al. The 1-year safety and efficacy outcomes of Absorb bioresorbable vascular scaffolds for coronary artery disease treatment in diabetes mellitus patients: the ABSORB DM Benelux study. Neth Heart J. 2019;27:541–9.

    Article  CAS  Google Scholar 

  14. Hommels TM, Hermanides RS, Rasoul S, et al. Everolimus-eluting bioresorbable scaffolds for treatment of coronary artery disease in patients with diabetes mellitus: the midterm follow-up of the prospective ABSORB DM Benelux study. Cardiovasc Diabetol. 2019;18:25.

    Article  CAS  Google Scholar 

  15. von Birgelen C, Basalus MW, Tandjung K, et al. A randomized controlled trial in second-generation zotarolimus-eluting Resolute stents versus everolimus-eluting Xience V stents in real-world patients: the TWENTE trial. J Am Coll Cardiol. 2012;59:1350–61.

    Article  Google Scholar 

  16. von Birgelen C, Sen H, Lam MK, et al. Third-generation zotarolimus-eluting and everolimus-eluting stents in all-comer patients requiring a percutaneous coronary intervention (DUTCH PEERS): a randomised, single-blind, multicentre, non-inferiority trial. Lancet. 2014;383:413–23.

    Article  Google Scholar 

  17. Cutlip DE, Windecker S, Mehran R, et al. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation. 2007;115:2344–51.

    Article  Google Scholar 

  18. Vranckx P, Cutlip DE, Mehran R, et al. Myocardial infarction adjudication in contemporary all-comer stent trials: balancing sensitivity and specificity Addendum to the historical MI definitions used in stent studies. Euro Intervention. 2010;5:871–4.

    PubMed  Google Scholar 

  19. Thygesen K, Alpert JS, Jaffe AS, et al. Third universal definition of myocardial infarction. J Am Coll Cardiol. 2012;60:1581–98.

    Article  Google Scholar 

  20. Hicks KA, Tcheng JE, Bozkurt B, et al. 2014 ACC/AHA key data elements and definitions for cardiovascular endpoint events in clinical trials: a report of the American College of Cardiology/American Heart Association task force on clinical data standards (writing committee to develop cardiovascular endpoints data standards). J Nucl Cardiol. 2015;22:1041–4.

    Article  Google Scholar 

  21. Konigstein M, Ben-Yehuda O, Smits PC, et al. Outcomes among diabetic patients undergoing percutaneous coronary intervention with contemporary drug-eluting stents: analysis from the BIONICS randomized trial. JACC Cardiovasc Interv. 2018;11:2467–76.

    Article  Google Scholar 

  22. Milojevic M, Serruys PW, Sabik JF 3rd, et al. Bypass surgery or stenting for left main coronary artery disease in patients with diabetes. J Am Coll Cardiol. 2019;73:1616–28.

    Article  Google Scholar 

  23. Konishi A, Mitsutake Y, Ho M, et al. Patient and lesion characteristics in late/very late stent thrombosis with everolimus-eluting stents from real-world adverse event reporting. J Cardiol. 2020;75:255–60.

    Article  Google Scholar 

  24. Kereiakes DJ, Ellis SG, Kimura T, et al. Efficacy and safety of the Absorb everolimus-eluting bioresorbable scaffold for treatment of patients with diabetes mellitus: results of the Absorb diabetic substudy. JACC Cardiovasc Interv. 2017;10:42–9.

    Article  Google Scholar 

  25. Tang XF, Ma YL, Song Y, et al. Biodegradable polymer drug-eluting stents versus second-generation drug-eluting stents in patients with and without diabetes mellitus: a single-center study. Cardiovasc Diabetol. 2018;17:114.

    Article  CAS  Google Scholar 

  26. Campos CM, Caixeta A, Franken M, et al. Risk and timing of clinical events according to diabetic status of patients treated with everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting stent: 2-year results from a propensity score matched comparison of ABSORB EXTEND and SPIRIT trials. Catheter Cardiovasc Interv. 2018;91:387–95.

    Article  Google Scholar 

  27. Anadol R, Schnitzler K, Lorenz L, et al. Three-years outcomes of diabetic patients treated with coronary bioresorbable scaffolds. BMC Cardiovasc Disord. 2018;18:92.

    Article  Google Scholar 

  28. Serruys PW, Chevalier B, Dudek D, et al. A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1-year analysis of clinical and procedural secondary outcomes from a randomised controlled trial. Lancet. 2015;385:43–54.

    Article  CAS  Google Scholar 

  29. Ellis SG, Kereiakes DJ, Metzger DC, et al. Everolimus-eluting bioresorbable scaffolds for coronary artery disease. N Engl J Med. 2015;373:1905–15.

    Article  CAS  Google Scholar 

  30. Kereiakes DJ, Ellis SG, Metzger C, et al. 3-Year clinical outcomes with everolimus-eluting bioresorbable coronary scaffolds: the ABSORB III trial. J Am Coll Cardiol. 2017;70:2852–62.

    Article  CAS  Google Scholar 

  31. Serruys PW, Chevalier B, Sotomi Y, et al. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): a 3 year, randomised, controlled, single-blind, multicentre clinical trial. Lancet. 2016;388:2479–91.

    Article  CAS  Google Scholar 

  32. Tijssen RYG, Kraak RP, Hofma SH, et al. Complete two-year follow-up with formal non-inferiority testing on primary outcomes of the AIDA trial comparing the Absorb bioresorbable scaffold with the XIENCE drug-eluting metallic stent in routine PCI. Euro Intervention. 2018;14:e426–33.

    PubMed  Google Scholar 

  33. Ortega-Paz L, Capodanno D, Gori T, et al. Predilation, sizing and post-dilation scoring in patients undergoing everolimus-eluting bioresorbable scaffold implantation for prediction of cardiac adverse events: development and internal validation of the PSP score. Euro Intervention. 2017;12:2110–7.

    PubMed  Google Scholar 

  34. Stone GW, Abizaid A, Onuma Y, et al. Effect of technique on outcomes following bioresorbable vascular scaffold implantation: analysis from the ABSORB trials. J Am Coll Cardiol. 2017;70:2863–74.

    Article  Google Scholar 

  35. Caixeta A, Campos CM, Felix C, et al. Predictors of long-term adverse events after Absorb bioresorbable vascular scaffold implantation: a 1,933-patient pooled analysis from international registries. EuroIntervention. 2019;15:623–30.

    Article  Google Scholar 

  36. Chevalier B, Cequier A, Dudek D, et al. Four-year follow-up of the randomised comparison between an everolimus-eluting bioresorbable scaffold and an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II trial). EuroIntervention. 2018;13:1561–4.

    Article  Google Scholar 

  37. Goel S, Pasam RT, Chava S, et al. Three to four years outcomes of the Absorb bioresorbable vascular scaffold versus second-generation drug-eluting stent: a meta-analysis. Catheter Cardiovasc Interv. 2020;95:216–23.

    Article  Google Scholar 

  38. Seth A, Onuma Y, Chandra P, et al. Three-year clinical and two-year multimodality imaging outcomes of a thin-strut sirolimus-eluting bioresorbable vascular scaffold: MeRes-1 trial. EuroIntervention. 2019;15:607–14.

    Article  Google Scholar 

  39. Qin Z, Zhou K, Li YP, et al. Remnant lipoproteins play an important role of in-stent restenosis in type 2 diabetes undergoing percutaneous coronary intervention: a single-centre observational cohort study. Cardiovasc Diabetol. 2019;18:11.

    Article  Google Scholar 

Download references

Acknowledgements

The study team is grateful to P.C. Koopmans, statistician and epidemiologist from Signidat, Groningen, The Netherlands, for contributing to the statistical analysis of this trial.

Funding

Department of Cardiology, Isala Hospital, Zwolle. Unrestricted research grant from Abbott Vascular and Boston Scientific.

Author information

Authors and Affiliations

Authors

Contributions

This manuscript is an original work and it is not under consideration for publication elsewhere. EK and TMH designed the study, co-drafted the manuscript and gave final approval, TMH performed statistical analysis, RSH, BB, EF, GL, EHP and CB critically revised the manuscript for intellectual content. All authors read and approved the final manuscript.

Corresponding author

Correspondence to E. Kedhi.

Ethics declarations

Ethics approval and consent to participate

The ABSORB DM Benelux Study (NTR5447) was performed in concurrence with the Declaration of Helsinki and was registered at the Netherlands Trial Register (NTR) acknowledged by the World Health Organization (WHO) and International Committee of Medical Journal Editors (ICMJE). The TWENTE (NTR1256/NCT01066650) and DUTCH PEERS (NTR2413/NCT01331707) trials were both conducted in concurrence with the Declaration of Helsinki and were registered at the NTR as well as at ClinicalTrials.gov. An approval for ethical committees was sought in all participating centers and countries. The clinical investigations did not test any non-approved device. The ABSORB BVS and the ABSORB GT1 are CE marked products and were used widely in daily clinical practice all over the world from 2009 to 2017. The Xience V EES is widely utilized since 2007 and the Promus Element EES since 2010. These clinical trials do not involve a medicinal product and are therefore not subject to The European Clinical Trials Directive (2001/20/EC).

Consent for publication

Not applicable.

Competing interests

E.H. Ploumen and C. von Birgelen indicated that the research department of Thoraxcentrum Twente has received institutional research grants from Abbott Vascular, Biotronik, Boston Scientific and Medtronic. The other authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hommels, T.M., Hermanides, R.S., Berta, B. et al. Everolimus-eluting bioresorbable scaffolds and metallic stents in diabetic patients: a patient-level pooled analysis of the prospective ABSORB DM Benelux Study, TWENTE and DUTCH PEERS. Cardiovasc Diabetol 19, 165 (2020). https://doi.org/10.1186/s12933-020-01116-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12933-020-01116-2

Keywords