Skip to main content

Table 5 Hemodynamic data during DSE scans in study 2

From: Glucagon-like peptide-1 protects against ischemic left ventricular dysfunction during hyperglycemia in patients with coronary artery disease and type 2 diabetes mellitus

 

Peak stress

Recovery

Control-HHC

GLP-1-HHC

P

Control-HHC

GLP-1-HHC

P

Heart rate (bpm)

126 ± 13

125 ± 9

0.83

71 ± 11

77 ± 9

0.14

Systolic blood pressure (mm Hg)

200 ± 25

206 ± 25

0.82

152 ± 22

146 ± 29

0.37

Diastolic blood pressure (mm Hg)

84 ± 24

81 ± 18

0.87

83 ± 14

84 ± 24

0.84

Rate-pressure product (mm Hg bpm)

25,177 ± 4,564

26,197 ± 3,883

0.92

10,733 ± 2,227

11,159 ± 2,788

0.54